SPELLMAN 파워 펌웨어 SWM1005-001 버전 이더넷 로그인 방법

 1. Connect the module to a computer using the ethernet cable

2. Turn on the AUX supply only.

3. Go to the “Network and Sharing Center” on your computer and click on the ethernet icon.

4. Go to properties in the ethernet status tab.

5. Click on “Internet Protocol Version 4(TCP/IPv4)

6. Change the IP address close to the default IP address of the ethernet module192.168.1.X. Here X can be any number between 1-255 except for 4.

7. Go to “Google Chrome” and type in the IP address: 192.168.1.4

8. A pop-up window will appear for username and password

9. Username: root; Password: shv

10. Once connected the following window will appear

11. Go to network settings to change the IP address

12. Change the IP as mentioned in the SCD, example

13. Click apply and click the reboot button

14. Do not restart the system! The reboot will automatically take place.

15. In order to connect with the new IP address, repeat the process of changing the system IP address on the computer

16. Once completed, type the new IP address in the chrome tab and connect

17. Cycle the power and make sure the IP address is connected.

18. Process is completed.